AURA Aroma Casa Diffuser (CD-2H) is designed with atomization technology, with a built-in intelligent PCB control program, the product can be placed independently, the product appearance is stylish and atmospheric, and the fragrance diffusion is accurate and stable. It’s main function is to create a different fragrance style for life, which is suitable for home, offices, shopping malls, stores, hotels, airports, and other places.

 

Attentions

Please read this manual in detail before using the device and keep it carefully.

1. Please do not use overloaded power sockets, broken wire and charger. It may endanger your safety and cause a fire, please replace in time if it happens.

2. Please do not try to modify, disassemble or repair the device in order to avoid damage to the device, if you are not a technician. If the device is abnormal, please check whether it is operated normally according to the user manual, or check according to the Malfunction Debugging. If it cannot be solved, please contact seller timely.

3. Please do not tilted or invert the device when used. If the device needs to be transported to other sites, please clean and maintain the device (see Maintenance for details) first before package and transportation, in case of oil leakage to damage the device.

4. Please maintain and clean the device regularly to ensure the device in best working states.

 

Instruction of Essential Oil

1. Before refill canister with essential oil, please turn off the device for 2 minutes till oil of atomizer back to canister then take off the oil canister.

2. It’s recommended to control the amount of essential oil and run out within 45 days, in order to avoid the deterioration of essential oils by oxidation.

Installation

1. Rotate the atomizer body ① counterclockwise, the atomizer body and essential oil bottle will automatically pop up, take out the atomizer body and essential oil bottle. ②

 

2. Hold the essential oil bottle and rotate it counterclockwise to take out the essential oil bottle to separate it from the main body of the atomizer, and fill it with essential oil (100ml, the upper limit). ③

 

3. Tighten the essential oil bottle containing the essential oil clockwise with the atomizer body. ④

 

4. Put the essential oil bottle and the atomization body into the control base, and tighten it clockwise (no need to correct the direction). ⑤

 

5. Set working hours and start using the equipment.

 

6. When the equipment is equipped with essential oils, it is forbidden to tilt.

Parameters

Description of LCD display

1. Operating instructions:

① Connect the power cord to the power adapter (5V-1A).       

② Insert the power cord into the DC POWER IN power inlet of the device.     

③ Plug the power adapter into the power socket, and the device is powered on.

 

2. Control instructions:

Firstly to press [SET], the LCD display showed "hours" figure will flash, then press [UP/DOWN] to adjust hour. Press [SET] at second time. Hour adjustment finished. The minutes figure will flash, then press [UP/DOWN] to adjust the minutes. Press [SET] at the third time, Minutes adjustment finished. The indicated date will flash, press [UP/DOWN] to adjust the cur-rent date, finally press [SET] at fourth time, all function setting finished. 

 

Set up the work time:

Set the working periods:

The machine can be set for 5 groups different working periods , it can also set different working days from Monday to Sunday according to different request. ( Such as working for Monday, Wednesday, Friday; Stop for Tuesday, Thursday, Saturday

 

• First time to press [MODE], the LCD display will show [EVENT ONE] means it is the START TIME of first group. Then, press [SET] to do the program setting, Press [UP/DOWN] to adjust the hours, minutes and needed working days group.

 

• Second time to press [MODE], the LCD display will show [EVENT 1 OFF] means the PAUSE TIME of first group. Then, press [SET] to do the program setting. Press [UP/DOWN] to adjust hours, minutes.

 

• Third time to press [MODE], the LCD display will show [SCENT WORK PAUSE] means the AROMA CONCENTRATION SMING of first group. Press [UP/DOWN] to adjust the aroma concentration. Every time you can adjust 5% ( such as 5%,10%,15%....), the maximum is 95%, the min-imum is 5%.

 

Notice:

1. for example 5% means it work for 10 seconds and stop for 190 seconds. 95% means it Work for 190 seconds and stop for 10 seconds. Means based on a period of 200 seconds totally for ON/OFF.

2. long press MODE button back to Factory Settings (60%). 3.Press SET for 10s to lock/open the PCB system settings.

 

TIP: If don't use the equipment for a long time, please clean the spray nozzle and internal parts. operation: add 95% alcohol to the empty oil bottle, set the machine to be 95% to work for 10-15 minutes . To clean the machine with 95% alcohol every two months.

 

Warranty

1.The Warranty is suitable for new machine but not resell or second hand products.

2.Within 12 months after purchase date, Warranty is offered for all qualified machines. During warranty, we will offer repair services and the free parts but without essential oil.

3.The warranty card & purchase Invoice are needed if after service required. Please contact with us within warranty if any problems.

4.The following is not for free warranty service:

① Damage & problems caused by Accidents & Fire.

② Not use properly and wrong operation.

③ If repaired by not professional person and make some parts damaged.

④ Damaged during transportation.

⑤ Without our warranty card.

⑥ Without proper cleaning for a long time

⑦ The machine work time out.

⑧ Machines & Parts not from us.

⑨ Machines not gotten from official channels.

⑩ Send the machines back without permit from manufacturer .

 

Notice

1.Please carefully read the Instruction before installation, and keep the User manual to check if need at anytime. 2.Please make sure the machine upright, no leaking and no down; or may damage the device and parts.

3.Please do not use the broken power wire and make sure the power supply is suitable for the machine, or may cause fire. 4.Please do not open the machine by yourself, If problems, please contact us promptly!

Screen Shot 2023-09-01 at 12.46.49 PM.png
Screen Shot 2023-09-01 at 12.50.47 PM.png
Screen Shot 2023-09-01 at 12.51.07 PM.png
Screen Shot 2023-09-01 at 12.55.30 PM.png
Screen Shot 2023-09-01 at 2.03.15 PM.png
bottom of page